2 Set-point System

set.jpg (16789 bytes)

 

Features

Two connections – signal outputs are provided, which are to be connected with appropriate relay box. These connections will send two signals according to the preset weight entered by the party. On receiving these signals from the scale, the relay will become ON or OFF and will operate valve or attached instrument as per party’s requirement.

 

For Setting Individual Setpoint

In normal weighting mode press "MR" key.

Scale will display "Set1".

Enter first setpoint value through up and side arrow keys.

Press "Tare" to accept and similarly enter the second setpoint.

The first setpoint should be smaller than the second one.

For Tolerance and Calibration

Tolerance value is used to control the overflow of material by activating the second setpoint early.

Turn the scale on while pressing "mode" key.

Display will show "Tolerance".

Enter the value by using up and side arrow keys.

After that scale will show "Cal?". If you want to recalibrate the scale, then proceed further as per calibration procedure mentioned in scale manual. Otherwise restart the scale.

Filling Procedure

The scale can be used in weighing mode without using the setpoints.

To use the setpoints, press "Mode" key, display will show "Start".

The first setpoint is activated and when the first value is reached, it is closed and the second is activated and similarly achieving the second value it is also closed.

Now to repeat the action press " Mode " key again.

Due to Alexandra Scale's policy of continuous development, these specifications are subject to change without notice